Shop Drawings
Every drawing we publish, in one place. Search by product, size or drawing number, or open a product to see its sheets.
182 drawings
Concrete Barrier
24 drawings
- Barrier Buying GuidePage 3
- Bull-Nose, 460 mm (CBN-H & CBN-E)Page 4
- Transition Barrier, 690 to 460 mm (CTB-1E)Page 5
- Transition Barrier, 810 to 690 mm (CTB-2H)Page 6
- Transition Barrier, 686 to 690 mm (CTB-3E+H)Page 7
- Transition Barrier, 686 to 690 mm (CTB-3H)Page 8
- Transition Barrier CTB-3E+H DetailsPage 9
- Bridge Parapet, 810 mm High TransitionPage 10
- Bridge Parapet, 810 mm High Transition DetailsPage 11
- Pier Barrier, 810 mm (CPB-E)Page 12
- Pier Barrier, 810 mm (CPB-H)Page 13
- Pier Barrier CPB-H & CPB-E DetailsPage 14
- Median Barrier, 810 mm (CMB-E)Page 15
- Median Barrier CMB-E DetailsPage 16
- Median Barrier, 810 mm (CMB-H)Page 17
- Median Barrier CMB-H DetailsPage 18
- Median Drainage Barrier, 810 mm (CMDB-E) DetailsPage 19
- Roadside Barrier, 690 mm (CRB-E)Page 20
- Roadside Barrier CRB-E DetailsPage 21
- Roadside Barrier, 690 mm (CRB-H)Page 22
- Roadside Barrier CRB-H DetailsPage 23
- Drainage Barrier, 690 mm (CDB-E) DetailsPage 24
- Low Barrier, 460 mm (CLB-E+H)Page 25
- 6 ft Parking Curb230 lbs / 104 kgPage 26
Electrical
36 drawings
- Lamp Bases: 4, 5, 6 and 8 ft (LSB4 to LSB8)Page 3
- Round LampbasePage 4
- Lamp Base Order TemplatePage 5
- Type C Concrete Base (BC MoTI SP635-1.1.3)Page 6
- Type CM Modified Type C Concrete Base (BC MoTI SP635-1.1.3a)Page 7
- Type D1 & E1 Concrete Spread Footings (BC MoTI SP635-1.1.4)Page 8
- Type D1 & E1 Concrete Spread Footings (BC MoTI SP635-1.1.5)Page 9
- Type D1 & E1 Concrete Spread Footings (BC MoTI SP635-1.1.6)Page 10
- Types D2 and E2 Concrete Bases, Precast (BC MoTI SP635-1.1.7)Page 11
- Type D2 and E2 Concrete Bases, Precast (BC MoTI SP635-1.1.8)Page 12
- Type D3 and E3 Concrete Bases, Cast in Place (BC MoTI SP635-1.1.9)Page 13
- Type D3 and E3 Concrete Bases, Cast in Place (BC MoTI SP635-1.1.10)Page 14
- Type F1, L1 & S1 Concrete Spread Footings (BC MoTI SP635-1.1.11)Page 15
- Type F1, L1 & S1 Concrete Spread Footings (BC MoTI SP635-1.1.12)Page 16
- Type F1, L1 & S1 Concrete Spread Footings (BC MoTI SP635-1.1.13)Page 17
- Type F2, L2 and S2 Concrete Bases, Precast (BC MoTI SP635-1.1.14)Page 18
- Type F2, L2 and S2 Concrete Bases, Precast (BC MoTI SP635-1.1.15)Page 19
- Anchor Bolt Cage for Type L Poles (BC MoTI SP635-1.1.19)Page 20
- Type M1 Concrete Spread Footing (BC MoTI SP635-1.1.20)Page 21
- Type M1 Concrete Spread Footing (BC MoTI SP635-1.1.21)Page 22
- Type M1 Concrete Spread Footing (BC MoTI SP635-1.1.22)Page 23
- Type M2 Concrete Base, Cast in Place (BC MoTI SP635-1.1.23)Page 24
- Type M2 Concrete Base, Precast or Cast in Place (BC MoTI SP635-1.1.24)Page 25
- Anchor Bolt Cage for Type M Poles (BC MoTI SP635-1.1.25)Page 26
- Type H1 Concrete Spread Footing (BC MoTI SP635-1.1.26)Page 27
- Type H1 Concrete Spread Footing (BC MoTI SP635-1.1.27)Page 28
- Type H1 Concrete Spread Footing (BC MoTI SP635-1.1.28)Page 29
- Type H2 Concrete Base, Precast or Cast in Place (BC MoTI SP635-1.1.29)Page 30
- Type H2 Concrete Base, Cast in Place (BC MoTI SP635-1.1.30)Page 31
- Anchor Bolt Cage for Type H Poles (BC MoTI SP635-1.1.31)Page 32
- Concrete Controller Base Details, Precast (BC MoTI SP635-1.1.38)Page 33
- Concrete Controller Base Rebar Details, Precast (BC MoTI SP635-1.1.39)Page 34
- Concrete Junction Box Details (BC MoTI SP635-1.3.1)Page 35
- Concrete Junction Box Details (BC MoTI SP635-1.3.2)Page 36
- Small Concrete Vault, 1020 Square x 1015 Deep (BC MoTI SP635-1.3.3)Page 37
- Concrete Vault, 1520 Square x 1230 Deep (BC MoTI SP635-1.3.4)Page 38
Headwall
12 drawings
- Type 1 Headwall & Grill3300 lbs (approx.)Page 3
- 11-13 HeadwallPage 4
- 11-13 Headwall & Inlet GratePage 5
- 11-13 Headwall & Outlet GratePage 6
- HW 16-20Page 7
- HW 16-20 HandrailPage 8
- HW 16-20 Trash RackPage 9
- Headwall Types HW-1 and HW-1A, General NotesPage 10
- HW 26-28Page 11
- HW 26-28 HandrailPage 12
- HW 26-28 Trash RackPage 13
- 3050 x 1525 mm Double HeadwallPage 14
Interlocking Block
8 drawings
London Boulder
14 drawings
- Big Block Landscape SolutionsPage 3
- About The London Boulder SystemPage 4
- LB42 Block TypesPage 5
- Design Considerations: Unreinforced Height LimitsPage 6
- Design Considerations: Nearby Structures, Terrain and SoilsPage 7
- Design Considerations: WaterPage 8
- Setback and Reinforced WallsPage 9
- Installation: Excavation and Base PreparationPage 10
- Installation: Setting The First CoursePage 11
- Installation: Backfill and Successive CoursesPage 12
- Installation: Geogrid, Curves and CornersPage 13
- Special Situations: Capping and 90 Degree CornersPage 14
- Free-Standing Partition Walls and SeawallsPage 15
- Wall Design OverviewPage 16
Manhole & Catch Basin
22 drawings
- 450 x 925 mm Lawn Basin630 lbs (approx.)Page 3
- 750 mm Catch BasinPage 4
- 750 mm Reinforced LidPage 5
- Catch Basin (BC MoTI SP582-02.01)Page 6
- 30 in Perforated DrywellPage 7
- 915 mm Catch BasinPage 8
- 915 mm Reinforced LidPage 9
- 1050 mm ManholePage 10
- 1050 mm Reinforced LidPage 11
- 1220 mm ManholePage 12
- 1220 mm Reinforced LidPage 13
- 1220 mm DrywellPage 14
- 1350 mm ManholePage 15
- 1525 mm ManholePage 16
- 1525 mm Reinforced LidPage 17
- 1830 mm ManholePage 18
- 1830 mm Reinforced LidPage 19
- 2135 mm ManholePage 20
- 2100 mm Manhole Slab TopPage 21
- 2440 mm ManholePage 22
- 3050 mm ManholePage 23
- 3050 mm Manhole BarrelPage 24
Miscellaneous
12 drawings
- Concrete Picnic TablePage 3
- Picnic Table No. 1 BasePage 4
- Round Picnic TablesPage 5
- Round Picnic Table InstallationPage 6
- 18 in Roadside Barrier2000 lbs / 900 kgPage 7
- Park BenchPage 8
- Park Bench EndsPage 9
- 8 ft Exposed Aggregate PlanterPage 10
- Round PlanterPage 11
- 3 ft PlanterPage 12
- Bird Bath180 lbs / 82 kgPage 13
- Monument MarkerPage 14
Outhouse
7 drawings
Septic
24 drawings
- 600 Imperial Gallon Septic TankSingle compartment: 6000 LBS/2722 KG Double compartment: 7000 LBS/3176 KGPage 3
- 800 Imperial Gallon Septic TankSingle compartment: 8000 LBS/3631 KG Double compartment: 9000 LBS/4075 KGPage 4
- 1000 Imperial Gallon Septic TankSingle compartment: 10,000 LBS/4528 KG Double compartment: 11,000 LBS/4981 KGPage 5
- 1200 Imperial Gallon Septic TankSingle compartment: 12,000 LBS/5433 KG Double compartment: 13,000 LBS/5886 KGPage 6
- 1400 Imperial Gallon Septic TankSingle compartment: 14,000 LBS/6339 KG Double compartment: 15,000 LBS/6792 KGPage 7
- 2000 Gallon TankPage 8
- 2000 Gallon Two Compartment TankPage 9
- 2500 Gallon TankPage 10
- 3000 Gallon TankPage 11
- 3000 Gallon Two Compartment TankPage 12
- 4000 Gallon TankPage 13
- 4000 Gallon Two Compartment TankPage 14
- 5000 Gallon TankPage 15
- 800 Gallon Pit Toilet TankPage 16
- Pit Toilet Floor SlabPage 17
- Distribution BoxPage 18
- Floor Drain & GratePage 19
- Polylok 12 in CoverPage 20
- Polylok 12 in RiserPage 21
- Polylok 24 in CoverPage 22
- Polylok 24 in RiserPage 23
- Polylok 12 x 24 RiserPage 24
- Polylok 24 in Safety ScreenPage 25
- Polylok 24 in Corrugated Pipe Adapter RingPage 26
Vault & Oil Separator
10 drawings
- 3152 VaultPage 3
- 3152 Vault: Structural Specification and Wheel LoadsPage 4
- 3152 Oil Interceptor, APIPage 5
- 4212 VaultPage 6
- 4212 Oil Interceptor, APIPage 7
- 5212 VaultPage 8
- 5212 Oil Interceptor, APIPage 9
- 5212.5 API Oil SeparatorPage 10
- 5212.5 Coalescing Plate Oil SeparatorPage 11
- 5213 Oil Interceptor, APIPage 12
Custom Precast: Project Examples
8 drawings
- Fish Barrier: Structural Notes and Isometric ViewPage 3
- Fish Barrier: Layout and Assembly DetailsPage 4
- Fish Barrier: Panels A, B, C and DPage 5
- Fish Barrier: Panels E, F, G and HPage 6
- Fish Barrier: Panel J, Slab and Connector DetailsPage 7
- Fish Barrier: Handrail and Connection DetailsPage 8
- 14.51 m Ungulate Guard: General ArrangementPage 9
- 14.51 m Ungulate Guard: Abutment and Deck DetailsPage 10
Headwall: Project Examples
4 drawings
Vault & Oil Separator: Project Examples
1 drawing
No drawing matches that. Call the office at 250-426-8162 and we'll find it, or draw it.
Get A Price On Your Job
Tell us the product, the size, how many and where it's going. Attach a drawing if you have one. The request goes straight to the office.
- Phone
- 250-426-8162
- Office
- Monday to Friday, 8 am to 5 pm. Closed 12 to 1.
- Address
- 601 Patterson Street West, Cranbrook BC, V1C 6T3
Open In Google Maps
